Committed to precision empowerment industry safety
Explosion-proof ventilation louver
+
  • Explosion-proof ventilation louver

Explosion-proof ventilation louver

Key words:

Explosion-proof ventilation louver

Service Hotline:

Case Details

Product Introduction:

The explosion-proof ventilation louver receives DC 24V power supply to open or close the explosion-proof ventilation louver. The explosion-proof ventilation louver has full machine explosion-proof certification and can operate safely and stably in gas explosion zone 2.

Features:

  • Fully automatic: After setting the parameters, it can operate independently without manual intervention.
  • High safety: It can prevent accidents during the exhaust process and promptly discharge hazardous gases, reducing safety risks.
  • Super weather-resistant: The product has undergone over 2000 hours of neutral salt spray testing and over 1000 hours of UV resistance testing, suitable for long-term use in coastal and strong UV exposure areas.
  • Easy installation: Simple structure, convenient installation.
  • Super durable: The product has passed a simulated 10-year high-temperature aging model test and verification.

 

Model Specifications:

Item

Parameters

Model

TPF04

TPF04B

TPF06

Material

Carbon Steel

Dimensions(mm)

Length 454 × Width 404 × Height58

Length 454 × Width 404 × Height57

Length 450 × Width 400 × Height 88

Opening Size(mm)

Length 410 × Width360

Control

Linked to open or close with explosion-proof exhaust fan

Working Temperature

-20℃ ~+60℃ (-40℃ @ 48H)

Storage Temperature

-30℃ ~+75℃

Working Humidity

≤ 85% RH,no condensation

Rated Voltage

DC 24V

Rated Power

60W

48W

20W

Protection Level

IP66

Corrosion Level

C5

Explosion-proof Marking

II 3G Ex ec IIC T5 Gc

Ex ec IIC T4 Gc

Ex db IIC T4 Gb

Product Certification

ATEX, CE, ETL, ROHS

IECEx

CCC

 

Product Certificate:

Application Scenarios


Project